Read Local Operation Mode (GetLocalOperationMode, 0x49)

With this command, the operating mode and communication profile of the lo-
cal Bluetooth
Conditions
Request
Byte
Response
Byte
Return values
Parameter
MBX_RESULT
MBX_OPMODE
_ID
MBX_
COMMROFILE
_ID
®
module are read.
Mailbox size
Operating mode/profile
6
12
18
Config.
7
6
5
2
2
2
0
MBX_GETLOCALOPERATIONMODE
1
T
7
6
5
2
2
2
0
MBX_GETLOCALOPERATIONMODE
1
T
2
MBX_OPMODE_ID
3
MBX_COMMROFILE_ID
Value
MBX_CMD_INVALID_ARG
MBX_CM_OPMODE_CONF (0x01)
MBX_CM_OPMODE_COMM (0x02)
MBX_CM_OPPROFILE_REALTIME (0x01)
MBX_CM_OPPROFILE_CONFIG (0x02)
MBX_CM_OPPROFILE_ADHOC (0x03)
Real-
Ad hoc
time
4
3
2
2
2
2
-
4
3
2
2
2
2
MBX_RESULT
Device role
Save
config.
Master
Slave
-
1
0
2
2
1
0
2
2
Description
Parameter value(s) invalid
Configuration mode
Communication mode
Real-time profile
Configuration profile