Inputs; Digital Input; Process Variables; Input - Siemens MASS 2100 Operating Instructions Manual

Sitrans f coriolis flowmeters
Hide thumbs Also See for MASS 2100:
Table of Contents

Advertisement

11.4

Inputs

11.4.1

Digital input

Table 11-11 Digital input
Description
Load
Functionality
11.4.2

Process variables

Table 11-12 Process variables
Description
Primary process varia‐
bles
Derived process varia‐
bles
11.4.3

Input

If the input is activated with a logic signal (15 - 30 V DC), the meter carries out an activity
selected in the menu.
The following input options are available:
● Start dosing
● Hold / continue dosing
– When this function is activated, it will pause the dosing. When it is deactivated, the
● Stop dosing
– Sets the digital output to "Off" and resets the dosing counter
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA
Channels 3 to 4
15 to 30 VDC, R
● Start/stop/hold/continue dosing
● Reset totalizer 1, 2 or 3
● Reset all totalizers
● Freeze output
Specification
● Massflow
● Density
● Fluid temperature
● Volumeflow
● Corrected volumeflow
● Fraction A:B
● Fraction % A:B
dosing will continue
7 kOhm
in
Technical data
11.4 Inputs
219