Siemens MASS 2100 Operating Instructions Manual page 381

Sitrans f coriolis flowmeters
Hide thumbs Also See for MASS 2100:
Table of Contents

Advertisement

HMI menu ID
Parameter
2.5.5.6.7
Partially Open Current
Level
2.5.5.6.8
Fully Open Current Lev‐
el
2.5.5.6.9
Fully Open
2.5.5.6.10
Partially Closed
2.5.5.6.9
Fully Open
2.5.5.6.10
Partially Closed
2.5.5.6.9
Fully Open
2.5.5.6.10
Partially Closed
2.5.5.6.9
Fully Open
2.5.5.6.10
Partially Closed
Table B-18
Recipe 2
HMI menu ID
Parameter
2.5.6.1
Name
2.5.6.2
Unit
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA
Description
Define current level to partly
close the analog valve.
Define current level to fully open
the analog valve.
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
Description
Define the name of the recipe.
Switching between recipes is
done in dosing operating view.
Select unit for the recipe. Unit is
not applied at communication in‐
terface.
Mass flow
Default value
Value range
[unit]
10
0 to 20
[mA]
20
0 to 20
[mA]
0.0
0.0 to100.0
[%]
0.0
0.0 to100.0
[%]
0.0
[kg]
1.0
[kg]
0.0
L
1.00
L
0.0
SI
1.00
SI
Default value
Value range
[unit]
kg
● g
● kg
● t
● STon
● T
● oz
● lb
● Custom
Default settings
B.6 Dosing
Access
level
User
User
User
User
User
User
User
User
User
User
Access
level
User
User
381

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc300Fct030

Table of Contents