Action
Sensor type incompatible. Please replace sen‐
sor.
Please wait until startup is finished. Startup time
see manual.
FW invalid. A component does not have the ex‐
pected FW version. Start a product firmware
update to update the component version.
Alarm class simulated. Disable Simulation be‐
fore returning to normal operation.
SensorFlash Chkdsk failed. Start Chkdsk
again. If error still exist replace SensorFlash.
FW invalid. A component does not have the ex‐
pected FW version. Start a product firmware
update to update the component version or re‐
place the component.
Input current too low. Check wiring and signal
of connected sensor or output source to input
channel.
Input current too high. Check wiring and signal
of connected sensor or output source to input
channel.
External failure. Connected sensor or output to
input channel is out of operation range. Please
check connected sensor or output source.
Diagnosing and troubleshooting
10.2 Fault codes and corrective actions
Comment
No detailed information avail‐
able in view Active diagnostic
events. Icon depends on simu‐
lated alarm class resp. NA‐
MUR status signal and the pri‐
ority in case of multiple alarm
classes simulated.
If Operation mode is config‐
ured to Current input.
If Operation mode is configur‐
edto Current input
If Operation mode is config‐
ured to Current input
203