Maximum Temperature Specifications For Ex Use - Siemens MASS 2100 Operating Instructions Manual

Sitrans f coriolis flowmeters
Hide thumbs Also See for MASS 2100:
Table of Contents

Advertisement

Safety notes
2.4 Use in hazardous areas
● Sensor and transmitter are connected to the potential equalization throughout the
hazardous area.
● EN/IEC 60079-14 is considered for installation in hazardous areas.
Further information and instructions including approval-specific special conditions for safe use
in Ex applications can be found in the certificates on the accompanying literature CD and at
the product web page (www.siemens.com/FC430).
Laying of cables
Explosion hazard
Cable for use in hazardous areas must satisfy the requirements for having a proof voltage of
at least 500 V AC applied between the conductor/ground, conductor/shield and shield/ground.
Connect the devices that are operated in hazardous areas as per the stipulations applicable
in the country of operation.
Field wiring installation
Ensure that the national requirements of the country in which the devices are installed are
met.
2.4.6

Maximum temperature specifications for Ex use

MASS2100 remote sensor
Temperature classification with and without dust is related to the process temperature and
ambient temperature as listed below.
The maximum allowable process fluid temperatures with respect to temperature class for the
device when used with potentially explosive gases.
Max media temperature [°C] versus temperature classification (T-ambient: -20 to +50 °C)
T6
T5
T4
T3
Additionally, the maximum surface temperature of the overall device shall be:
● For dust application, maximum surface temperature = 135°C
● For media temperature above 135°C surface temperature = media temperature
24
WARNING
WARNING
Maximum Process Temperature per Temperature Class (°C)
Di1/1.5/2.1/3
75
100
135
180
Di6
46
100
135
180
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA
Di15
38
100
135
180