For MASS 2100 compact with either FCT010 or FCT030
Ambient
Temperature
50°C
45°C
40°C
35°C
30°C
● For dust application, maximum surface temperature = 135°C
● For media temperature above 135°C surface temperature = media temperature
FC300
T3 for liquid temperatures from 135°C to 180°C.
T4 for liquid temperatures lower than 135°C.
T5 for liquid temperatures lower than 100°C.
T6 for liquid temperatures up to 65°C.
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA
Maximum Process Temperature per Temperature Class (°C)
Di3
Di6
T6
T6
75
46
80
51
85
56
85
61
85
66
Di15
T6
T5
38
100
43
100
48
100
53
100
58
100
Safety notes
2.4 Use in hazardous areas
T4
T3
130
130
135
160
135
180
135
180
135
180