Siemens MASS 2100 Operating Instructions Manual page 402

Sitrans f coriolis flowmeters
Hide thumbs Also See for MASS 2100:
Table of Contents

Advertisement

Default settings
B.6 Dosing
HMI menu ID
Parameter
2.5.9.6.3
Stage 1 Primary Close
2.5.9.6.4
Stage 2 Secondary
Open
2.5.9.6.5
Stage 2 Secondary
Close
2.5.9.6.6
Fully Closed Current
Level
2.5.9.6.7
Partially Open Current
Level
2.5.9.6.8
Fully Open Current Lev‐
el
2.5.9.6.9
Fully Open
2.5.9.6.10
Partially Closed
2.5.9.6.9
Fully Open
2.5.9.6.10
Partially Closed
2.5.9.6.9
Fully Open
2.5.9.6.10
Partially Closed
2.5.9.6.9
Fully Open
2.5.9.6.10
Partially Closed
2.5.9.7
Fault Handling
2.5.9.7.1
Duration mode
402
Description
Define the dosing amount value
to close the primary valve. The
value is in % of defined dosing
amount.
Define the dosing amount value
to open the secondary valve.
The value is in % of defined dos‐
ing amount.
Define the dosing amount value
to close the secondary valve.
The value is in % of defined dos‐
ing amount.
Define current level to fully close
the analog valve.
Define current level to partly
close the analog valve.
Define current level to fully open
the analog valve.
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
Enable or disable dosing time
supervision. An alarm is raised
and valve(s) closed if dosing
time is exceeded.
Default value
Value range
[unit]
1.00
SL
0.20
SL
0.80
SL
0
0 to 20
[mA]
10
0 to 20
[mA]
20
0 to 20
[mA]
0.0
0.0 to100.0
[%]
0.0
0.0 to100.0
[%]
0.0
[kg]
1.0
[kg]
0.0
L
1.00
L
0.0
SL
1.00
SL
Off
● Off
● On
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA
Access
level
User
User
User
User
User
User
User
User
User
User
User
User
User
User
User