Table 11-6
Additional error by deviations from reference conditions
Sensor size
DI 1.0
Effect of ambient
< ±0.003
temperature
[% / K actual flow‐
rate]
Current: < ±0.005
Effect of power sup‐
None
ply fluctuations
[% of measuring val‐
ue on 1% alteration
from Un]
Table 11-7
Process media conditions
Sensor size
DI 1.0
Process media tem‐
perature (T
) (min to
-50 °C to + 125 °C (-58 °F to +
s
max)
257 °F)
● Standard [°C
(°F)]
● High-
n/a
temperature
version [°C (°F)]
Process media den‐
n/a
sity (min to max) [g/
cm
(lb/inch
]
3
3
Process media
800 bar
gauge max pressure
at 20 °C
316L sensors [bar
640 bar
(psi)]
at 180 °C
(Derat‐
ing is lin‐
ear)
Process media
n/a
gauge max pressure
Hastelloy C22 sen‐
sors [bar (psi)]
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA
DI 1.5
DI 2.1
DI 3
< ±0.003
< ±0.003
< ±0.003
< ±0.005
< ±0.005
< ±0.005
None
None
<0.005% None
DI 1.5
DI 2.1
DI 3
-50 °C to
+ 180 °C
(-58 °F to
+ 356 °F)
-50 °C to
n/a
+ 180 °C
(-58 °F to
+ 356 °F)
0 ... 2.9 g/cm3 (0 ... 0.105 lb/
inch3)
230 bar
100 bar
230 bar
at 20°C
at 20 °C
at 20°C
(68 °F)
(3336
(3336
PSI at 68
PSI at 68
°F)
°F)
365 bar
n/a
350 bar
at 20 °C
at 20°C
(5294
(5076
PSI at 68
PSI at 68
°F)
°F)
DN4 HP
DN4 C22
DN4 316
(DI 2.0)
(DI 3.0)
(DI 3.5)
< ±0.003
< ±0.003
< ±0.003
< ±0.005
< ±0.005
< ±0.005
None
None
DN4 HP
DN4 C22
DN4 316
(DI 2.0)
(DI 3.0)
(DI 3.5)
-40 °C to
-40 °C to + 115 °C
+ 115 °C
(-40 °F to + 239 °F)
(-40 °F to
+ 239 °F)
-40 °C to + 180 °C
(-40 °F to + 356 °F)
n/a
0 ... 2.9 g/cm3 (0 ... 0.105 lb/inch3)
n/a
n/a
130 bar
(1885
psi)
at
20-180
°C (68
°F-356
°F)
1000 bar
410 bar
n/a
at max
(5945
20°C
psi)
(14503
at
psi)
20-180
°C (68
°F-356
°F)
Technical data
11.2 Performance
DI 6
DI 15
< ±0.003
< ±0.003
< ±0.005
< ±0.005
<0.005% <0.005%
DI 6
DI 15
-50 °C to + 180 °C
(-58 °F to + 356 °F)
265 bar
130 bar
at 20°C
at 20°C
(3844
(1885
PSI at 68
PSI at 68
°F)
°F)
410 bar
200 bar
at 20°C
at 20°C
(5946
(2900
PSI at 68
PSI at 68
°F
°F)
217