Operating MASS 2100/FC300 with FCT030
7.2 Operating instructions
Numeric parameters edit view
Numeric parameters in edit view are displayed as shown here.
3
4
6
7
Figure 7-6
Note
##### signs in display
The display is unable to show the measured value. Change the measurement unit or the
resolution.
Changing a value:
1. Select the digit to be changed by pressing
2. Use
3. Press
position to escape the view without changing the value.
Note
Ensure that the new value is within the minimum/maximum range.
Changing the resolution:
1. Select decimal point by pressing
2. Move decimal point by pressing
decimal point to the right).
130
1
8
Parameter name
Parameter item number
Maximum value
Escape without saving (frame around ESC is only shown when cursor is in left-most position)
Confirm and save (frame around OK is only shown when cursor is in right-most position)
Value to be edited
Minimum value
Help text describing the parameter function. The help text appears if no key is pressed for three
seconds.
Numeric parameter edit view
key to increase the value and
key in the rightmost position to confirm the changes, or press
2
5
and
keys.
key and decrease the values.
and
keys.
key (moves decimal point to the left) or
Operating Instructions, 06/2017, A5E39789040-AA
key in the leftmost
key (moves
MASS 2100 & FC300 (FCT030)