Network Connection and IP Address Requirements for Oracle Exadata Storage Expansion Rack
1 Ethernet connection for each Sun Datacenter InfiniBand Switch 36.
1 Ethernet connection for each Exadata Storage Server. For Oracle Exadata
Storage Expansion Full Rack, there are 18 connections, for Oracle Exadata
Storage Expansion Half Rack there are 9 connections, and for Oracle Exadata
Storage Expansion Quarter Rack there are 4 connections.
1 Ethernet connection for the Ethernet switch in the rack to the existing
management network.
1 Ethernet connection for each of the two PDUs. Network connectivity to the
PDUs is only required if the electric current is monitored remotely.
Management network connection requirements for Oracle Exadata Storage
Expansion Rack X3-2
1 Ethernet connection from the ILOM to each Exadata Storage Server. For
Oracle Exadata Storage Expansion Full Rack, there are 18 connections, for
Oracle Exadata Storage Expansion Half Rack there are 9 connections, and for
Oracle Exadata Storage Expansion Quarter Rack there are 4 connections.
1 Ethernet connection for each Sun Datacenter InfiniBand Switch 36.
1 Ethernet connection for each Exadata Storage Server. For Oracle Exadata
Storage Expansion Full Rack, there are 18 connections, for Oracle Exadata
Storage Expansion Half Rack there are 9 connections, and for Oracle Exadata
Storage Expansion Quarter Rack there are 4 connections.
1 Ethernet connection for the Ethernet switch in the rack to the existing
management network.
1 Ethernet connection for each of the two PDUs. Network connectivity to the
PDUs is only required if the electric current is monitored remotely.
Management network connection requirements for Oracle Exadata Storage
Expansion Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers
1 Ethernet connection from the ILOM to each Exadata Storage Server. For
Oracle Exadata Storage Expansion Full Rack, there are 18 connections, for
Oracle Exadata Storage Expansion Half Rack there are 9 connections, and for
Oracle Exadata Storage Expansion Quarter Rack there are 4 connections.
1 Ethernet connection for each Sun Datacenter InfiniBand Switch 36.
1 Ethernet connection for each Exadata Storage Server. For Oracle Exadata
Storage Expansion Full Rack, there are 18 connections, for Oracle Exadata
Storage Expansion Half Rack there are 9 connections, and for Oracle Exadata
Storage Expansion Quarter Rack there are 4 connections.
1 Ethernet connection for the Ethernet switch in the rack to the existing
management network.
1 Ethernet connection for the KVM switch in the rack to the existing
management network. This connection is only for Oracle Exadata Database
Machine X2-2 racks.
1 Ethernet connection for each of the two PDUs. Network connectivity to the
PDUs is only required if the electric current is monitored remotely.
The following table lists the IP address requirements for Oracle Exadata Storage
Expansion Racks:
Chapter 1
1-73