Firmware state:Online, Spun Up
Slot Number:8
Firmware state:Online, Spun Up
Slot Number:9
Firmware state:Online, Spun Up
Slot Number:10
Firmware state:Online, Spun Up
Slot Number:11
Firmware state:Online, Spun Up
[root@cell01 ~]#
Verify the flash modules are visible using the following command. There are four
5.
cards, and four modules per card.
# lsscsi |grep -i marvel
# cellcli -e list lun where disktype=flashdisk
The numbering shows the PCI slot number and FMOD number, such as
slot 1, FMOD 0 on the card. To confirm the flash disks are mapped that way, use
the following command:
# cellcli -e list physicaldisk attributes name, id, slotnumber where \
disktype="flashdisk" and 'status! ="not present"'
If any FMODs are missing, then power cycle the system, and wait 10 minutes after
starting to check. If this does not resolve the problem, then reseat the module and
flash card. If the problem continues, then replace the card with the on-site spare.
Check the rear of the rack to ensure the flash card LEDs are green all the way
6.
across. These LEDs are FMOD, 0, 1, 2, 3, and SuperCAP. If any LED is amber,
then check again after the next step. If the LED is still amber after restart, then
reseat the card and ESM or FMOD. If the problem continues, then replace the
card with the on-site spare.
Log out of the system using the following command:
7.
# logout
Return to the User Interface on the KVM switch by pressing the Ctrl key on the left
8.
to return to the KVM switch, and select Disconnect Session, if using the KVM
switch to access the server.
Select Target Devices from Unit View, if using the KVM switch to access the
9.
server.
Proceed to the next Exadata Storage Server.
10.
5.5 Checking Oracle Database Servers
The following procedure describes how to check the Oracle Database servers. At this
point, the operating system is Linux.
Log in as the
1.
Note:
This step can be done when all systems are on. It does not have to be done
on a per-server basis.
user to the first database server.
root
Chapter 5
Checking Oracle Database Servers
is PCI
1_0
5-57
Need help?
Do you have a question about the EXADATA X6-2 and is the answer not in the manual?
Questions and answers