Ethernet Link Object (Class Id: F6 Hex) - Omron NY532-5400 User Manual

Ny-series ipc machine controller industrial panel pc / industrial box pc
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

8-5-4

Ethernet Link Object (Class ID: F6 Hex)

This object is used to set and read Ethernet communications and read Ethernet communications status
information.
Service Codes
Specify the service to execute with the service code.
Service
Parameter name
code
0E hex
Get_Attribute_Single
10 hex
Set_Attribute_Single
4C hex
Get_and_Clear
Class ID
Specify F6 hex.
Instance ID
Specify 00 to 02 hex.
00: Specify the class
01: Built-in EtherNet/IP port
02: Internal port
Attribute ID
The attribute ID specifies the information to read.
 Class Attribute ID
The class attribute ID specifies the attribute of the entire object.
Attribute ID
Parameter name
01 hex
Revision
02 hex
Max Instance
03 hex
Num of Instance
 Instance Attribute ID
The instance attribute ID specifies the attribute of the instance.
Attribute ID
Parameter name
01 hex
Interface Speed
02 hex
Interface Flags
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
Description
Reads the value of the specified attribute.
Writes a value to the specified attribute.
Specify Attribute4 or Attribute5 to reset the value of the attribute to 0.
Description
Revision of the object
The maximum instance number
The number of object instance
Description
Gives the baud rate for the inter-
face.
Gives the status of the interface.
8 CIP Message Communications
Supported.
Supported.
Read data
Attribute
Data
type
Read
UINT
0004 hex
Read
UINT
0002 hex
Read
UINT
0002 hex
Read/write data
Attribute
Data
type
Read
UDINT
Reads the current value.
Read
DWORD
Refer to (1) Interface Flag Details,
below.
Supported services
Classes
Instances
Supported.
Supported.
Not sup-
Supported.
ported.
8
Value
Value
8-47