3 System-defined Variables Related to the Built-in EtherNet/IP Port
Variable name
Meaning
_EIP1_EtnOnlineSta
Port1 Online
_EIPIn1_EtnOnlin-
Internal Port1 Online
eSta
_EIP_TDLinkRunSta
Tag Data Link Com-
munications Status
_EIP_TDLinkAllRun-
All Tag Data Link
Sta
Communications Sta-
tus
_EIP_RegTargetSta
Registered Target
[255]
Node Information
_EIP_EstbTargetSta
Normal Target Node
[255]
Information
3-10
Function
Indicates that the built-in EtherNet/IP
port's communications can be used via
the communications port 1 (that is, the link
is ON, IP address is defined, and there
are no errors).
TRUE: The built-in EtherNet/IP port's
communications can be used.
FALSE: The built-in EtherNet/IP port's
communications is disabled due
to an error in initial processing,
restart processing, or link OFF
status.
Indicates that the built-in EtherNet/IP
port's communications can be used via
the internal port 1 (that is, the link is ON,
IP address is defined, and there are no
errors.)
TRUE: The built-in EtherNet/IP port's
communications can be used.
FALSE: The built-in EtherNet/IP port's
communications is disabled due
to an error in initial processing,
restart processing, or link OFF
status.
NY-series Controller: Indicates that at
least one connection is in normal opera-
tion in CIP communications 1.
TRUE: Normal operation
FALSE: Other than the above.
NY-series Controller: Indicates that all tag
data links are communicating in CIP com-
munications 1.
TRUE: Tag data links are communicating
in all connections as the origina-
tor.
FALSE: An error occurred in at least one
connection.
NY-series Controller: Gives a list of nodes
for which built-in EtherNet/IP connections
are registered for CIP communications 1.
This variable is valid only when the built-in
EtherNet/IP port is the originator.
Array[x] is TRUE:
The connection to the node with a tar-
get node ID of x is registered.
Array[x] is FALSE:
The connection to the node with a tar-
get node ID of x is not registered.
NY-series Controller: Gives a list of nodes
that have normally established Ether-
Net/IP connections for CIP communica-
tions 1.
Array[x] is TRUE:
The connection to the node with a target
node ID of x was established normally.
Array[x] is FALSE:
The connection to the node with a tar-
get node ID of x was not established, or
an error occurred.
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
Range of
Data type
values
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
ARRAY
TRUE or
[0..255] OF
FALSE
BOOL
ARRAY
TRUE or
[0..255] OF
FALSE
BOOL
Reference
page 3-21
page 3-21
page 3-21
page 3-21
page 3-22
page 3-22