Omron NY532-5400 User Manual page 82

Ny-series ipc machine controller industrial panel pc / industrial box pc
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

3 System-defined Variables Related to the Built-in EtherNet/IP Port
Variable name
_EIP_TagAdrErr
Meaning
Tag Name Resolution Error
Function
NY-series Controller: Indicates that tag resolution for CIP communications 1 failed (i.e., the address could not be identi-
fied from the tag name).
TRUE: Tag resolution failed (i.e., the address could not be identified from the tag name). The following causes are
possible.
FALSE: Other than the above.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP_MultiSwONErr
Meaning
Multiple Switches ON Error
Function
NY-series Controller: Indicates that more than one switch turned ON at the same time in CIP communications 1.
TRUE: More than one data link start/stop switch changed to TRUE at the same time.
FALSE: Other than the above.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP_TcpAppCfgErr
Meaning
TCP Application Setting Error
Function
TRUE: At least one of the set values for a TCP application (FTP, NTP, SNMP) is incorrect. Or, a read operation
failed.
FALSE: Normal.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP_NTPSrvErr
Meaning
NTP Server Connection Error
Function
Always FALSE for an NY-series Controller.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP_DNSSrvErr
Meaning
DNS Server Connection Error
Function
TRUE: The DNS client failed to connect to the server (timeout).
FALSE: DNS is not enabled. Or, DNS is enabled and the connection was successful.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
3-20
•The size of the network variable is different from the tag settings.
•The I/O direction that is set in the tag data link settings does not agree with the I/O direction of the vari-
able in the Controller.
•There is no network variable in the Controller that corresponds to the tag setting.
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
1

Advertisement

Table of Contents
loading

Table of Contents