Ethernet/Ip Communications Procedures - Omron NY532-5400 User Manual

Ny-series ipc machine controller industrial panel pc / industrial box pc
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

1-5
EtherNet/IP Communications
Procedures
 Basic Operation
1
Wire the Ethernet network with twisted-pair cable.
2
Set the built-in EtherNet/IP port IP address with the Sysmac Studio.
1. Use the Sysmac Studio to create a new project.
2. Set the local IP address in one of the following ways:
• Defaults:
Built-in EtherNet/IP port 1
Internal port
• Set any IP address.
• Obtain from BOOTP server.
3
Perform a communications test with a PING command from a com-
puter.
4
Use the Sysmac Studio to set the initial settings of the EtherNet/IP
Function Module.
Set the TCP/IP settings and Ethernet settings as required.
 Using Tag Data Links
1
Import the variable settings for the tags that were created on the
Sysmac Studio to the Network Configurator.
2
Use the Network Configurator to create the tag data link table.
• Create the network configuration.
• Set the tags, tag sets, and connections.
3
Connect the Network Configurator online.
4
Download the tag data link setting.
5
Start the tag data links (the links starts automatically when power is
turned ON).
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
: 192.168.250.1
(subnet mask = 255.255.255.0)
: 192.168.254.1
(subnet mask = 255.255.255.0)
1 Introduction
Section 2 Installing Ethernet
Networks
Section 4 Determining IP
Addresses
Section 6 Testing Communi-
cations
Section 5 Sysmac Studio
Settings for the Built-in Eth-
erNet/IP Port
7-2-4 Creating Tags and Tag
Sets
Section 7 Tag Data Link
Functions
1-21