Omron NY532-5400 User Manual page 77

Ny-series ipc machine controller industrial panel pc / industrial box pc
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

Variable name
_EIPIn1_PortErr
Meaning
Internal Port1 Error
Function
This is the error status variable for the internal port 1.
It represents the collective status of the following error flags.
• _EIPIn1_IPAdrCfgErr (Internal Port1 IP Address Setting Error)
• _EIP1_IPAdrDupErr (Internal Port1 IP Address Duplication Error)
• _EIP_DNSCfgErr (DNS Setting Error)
• _EIP_DNSSrvErr (DNS Server Connection Error)
• _EIP_IPRTblErr (IP Route Table Error)
Note If a Link OFF Detected or Built-in EtherNet/IP Processing Error occurs, it is recorded in the event log and
then corresponding bit turns ON. Refer to Meanings of Error Status Bits for the meanings of the error status
bits.
Data type
WORD
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP_CipErr
Meaning
CIP Communications Error
Function
This is the error status variable for CIP communications.
Note If a Tag Name Resolution Error occurs, it is recorded in the event log and this variable changes to TRUE.
Data type
WORD
R/W access
R
Usage in user program
Possible.
Variable name
_EIP_TcpAppErr
Meaning
TCP Application Communications Error
Function
This is the error status variable for TCP application communications.
It represents the collective status of the following error flags.
• _EIP_TcpAppCfgErr (TCP Application Setting Error)
• _EIP_NTPSrvErr (NTP Server Connection Error)
Note Refer to Meanings of Error Status Bits for the meanings of the error status bits.
Data type
WORD
R/W access
R
Usage in user program
Possible.
Variable name
_EIP_MacAdrErr
Meaning
MAC Address Error
Function
NY-series Controller: Indicates that an error occurred when the MAC address was read on the communications
port 1 at startup.
TRUE: Error
FALSE: Normal
Data type
BOOL
R/W access
R
Usage in user program
Possible.
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
3 System-defined Variables Related to the Built-in EtherNet/IP Port
Retained
Not retained.
Related
You can access this variable from the user program with the following instruction.
instructions
• GetEIPError
Refer to Meanings of Error Status Bits for the meanings of the error status bits.
Retained
Related instruc-
tions
Retained
Not retained.
Related
You can access this variable from the user program with the following instruc-
instructions
tion.
• GetEIPError
Retained
Not retained.
Related
---
instructions
Global/local
Range of values
Network Publish
Global/local
Range of values
Not retained.
Network Publish
You can access this variable from the user program with the following
instruction.
• GetEIPError
Global/local
Range of values
Network Publish
Global/local
Range of values
Network Publish
Global
16#0000 to 16#00F0
Published.
Global
16#0000 to 16#00F0
Published.
Global
16#0000 to 16#00F0
Published.
Global
TRUE or FALSE
Published.
3
3-15

Advertisement

Table of Contents
loading

Table of Contents