 Number of Tags in Tag Sets
You can set any tag sets containing one or more tags for the input and output tag sets for one con-
nection. For example, you can set a tag set with one tag for the input tag set and set a tag set with
more than one tag for the output tag set.
Tag Sets with Only One Tag Each
With basic Network Configurator procedures, each tag set contains only one tag.
NY-series Controller
Variable a
Variable b
Tag Sets Each with Multiple Tags
As shown below, tags can be grouped. You can place up to eight tags (up to 722 words in total) in
one tag set.
NY-series Controller
Variable a
Variable b
Variable c
Variable d
Variable e
Note To enable a connection, each tag set must include only input tags or only output tags. (Both input and output
tags cannot be included in the same tag set.)
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
Tag set SP1_IN
Tag set SP1_OUT
(tag a)
Connection
Tag set SP2_OUT
Tag set SP2_IN
(tag b)
Connection
EtherNet/IP
Tag set SP1_IN
(group of tags a, b, and c)
Tag set SP1_OUT
Connection
Tag set SP2_OUT
Tag set SP2_IN
(group of tags d and e)
Connection
EtherNet/IP
7 Tag Data Link Functions
CJ-series CPU Unit
I/O memory
(tag c)
Variable c
(tag d)
Variable d
CJ-series CPU Unit
I/O memory
Variable f
Variable g
Variable h
Variable i
Variable j
Individual tags