Omron NY532-5400 User Manual page 78

Ny-series ipc machine controller industrial panel pc / industrial box pc
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

3 System-defined Variables Related to the Built-in EtherNet/IP Port
Variable name
_EIP1_MacAdrErr
Meaning
Port1 MAC Address Error
Function
Indicates that an error occurred when the MAC address was read on the communications port 1 at startup.
TRUE: Error
FALSE: Normal
Data type
BOOL
R/W access
R
Usage in user program
Possible.
Variable name
_EIP_LanHwErr
Meaning
Communications Controller Error
Function
NY-series Controller: Indicates that a communications controller failure occurred on the communications port 1.
TRUE: Failure
FALSE: Normal
Data type
BOOL
R/W access
R
Usage in user program
Possible.
Variable name
_EIP1_LanHwErr
Meaning
Port1 Communications Controller Error
Function
Indicates that a communications controller failure occurred on the communications port 1.
TRUE: Failure
FALSE: Normal
Data type
BOOL
R/W access
R
Usage in user program
Possible.
Variable name
_EIP_EtnCfgErr
Meaning
Basic Ethernet Setting Error
Function
NY-series Controller: Indicates that the Ethernet communications speed setting (Speed/Duplex) for the communi-
cations port 1 is incorrect. Or, a read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Data type
BOOL
R/W access
R
Usage in user program
Possible.
Variable name
_EIP1_EtnCfgErr
Meaning
Port1 Basic Ethernet Setting Error
Function
Indicates that the Ethernet communications speed setting (Speed/Duplex) for the communications port 1 is incor-
rect. Or, a read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Data type
BOOL
R/W access
R
Usage in user program
Possible.
3-16
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.

Advertisement

Table of Contents
loading