• Output Tag Set and Input Tag Set Tab Pages
You can monitor the status of each input/output tag set that is used for the EtherNet/IP con-
nections.
Note The tag set status monitor is not available for a built-in EtherNet/IP port on NJ-series Controller
version 1.08 or earlier.
Click  of each tag to display its detailed information.
Tag Set Name
Tag set size
Connected time
Unconnected time
Number of connections (in
the Output Tag Set Tab
Page)
Number of connected orig-
inators (in the Output Tag
Set Tab Page)
Originator list (in the Out-
put Tag Set Tab Page),
Target list (in the Input Tag
Set Tab Page)
Originator name (in the
Output Tag Set Tab
Page), Produced tag
name (in the Input Tag
Set Tab Page)
IP address (in the Out-
put Tag Set Tab Page),
Remote IP address (in
the Input Tag Set Tab
Page)
Connected time (in the
Output Tag Set Tab
Page)
Unconnected time (in
the Output Tag Set Tab
Page)
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
Name
Gives the connection status.
If there is a connection error, "Not connected or error" is given.
Gives the size of the tag set in bytes.
Gives the total connection duration in milliseconds.
Gives the total disconnection duration in milliseconds.
Gives the number of connections.
Gives the number of the connected originator devices.
Gives the detailed information of the connected originators.
Gives no information.
Gives the IP addresses allocated for the originators.
Gives the total duration of connection with the originator in milliseconds.
Gives the total duration of disconnection with the originator in millisec-
onds.