Drag the target device tag set Net_Out1 in the Variable Name column of the Toolbox to the con-
nection list.
As you enter characters (or immediately after you press the Ctrl + Space Keys), a list of target
device variables that can be set for the connection is provided. Select the value from the list.
6
Specify Originator Variable and its Size [Byte] for the tag set Net_Out1 added in step 5.
Here, specify Net_In1 for Originator Variable and 2 for its Size [Byte].
Change the other settings as required.
You can set the following items in the connection settings.
Target Device
Connection Name
Connection I/O Type
Input/Output
Target Variable
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
Name
Select the target device.
Any name can be given to the connection (32 single-byte characters
max.).
Input Only (Tag type) is selected if EtherNet/IP connections are used
with a CS1W-EIP21, CJ1W-EIP21, CJ2B-EIP21, CJ2M-EIP21, CJ1W-
EIP21(CJ2), CJ1W-EIP21(NJ), NX701, NJ501-, NJ301-
, NJ101, or NY52.
When you create EtherNet/IP connections for other target devices,
select the connection I/O type specified in that device's EDS file.
Use the Input Only (ID type) setting when another company's node is
the originator and does not support connection settings with a Tag type
setting.
The connection's input/output is automatically displayed based on the
selected connection.
Input Only: Just Input is displayed.
Select the target node's tag set to assign it.
• Input is specified for Input/Output: Select the target's output (pro-
duce) tag set.
• Output is specified for Input/Output: Select the target's input (con-
sume) tag set.