7-2-3

Registering Devices

Register all of the devices required in the equipment (such as EtherNet/IP Units performing tag data
links) in the network configuration.
1
Register the devices that will participate in the tag data links by dragging the devices from the
Hardware List and dropping them in the Network Configuration Pane on the right. (To drag and
drop an icon, click and hold the left mouse button over the icon, move the icon to the destina-
tion, and release the mouse button.)
You can also select a device in the Hardware List and press the Enter Key to register it. The
icon of the device is displayed in the Network Configuration Pane, as shown in the following dia-
gram.
The device names and major CIP revisions (Rev ) are displayed in the hardware list. For NY-series
Controller, device names and major CIP revisions are as shown in the following table.
Device name in
hardware list
NY512
NY532
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
Unit version
Unit version 1.12 or later
Unit version 1.12 or later
7 Tag Data Link Functions
Drag icons from the
hardware list. Select
device icons with the
same major CIP
revision (Rev
CIP revisions
Major revision
Revision name in hardware list
2
None
2
None
).
7-19