8 CIP Message Communications
Attribute ID
Parameter name
0C hex
HC Interface Counters
HCInOctets
HCInUnicastPkts
HCInMulticastPkts
HCInBroadcastPkts
HCOutOctets
HCOutUnicastPkts
HCOutMulticastPkts
HCOutBroadcastPkts
0D hex
HC Media Counters
HCStatsAlignmentErrors
HCStatsFCSErrors
HCStatsInternalMac
TransmitErrors
HCStatsFrameTooLongs
HCStatsMacReceiveEr-
rors
HCStatsMacSymbolEr-
rors
8-50
Description
The number of packets
sent/received through the HC
interface.
The number of octets received
through the interface.This counter
is the 64-bit edition of In Octets.
The number of unicast packets
received through the interface.
This counter is the 64-bit edition
of In Ucast Packets.
The number of multicast packets
received through the interface.
The number of broadcast packets
received through the interface.
The number of octets sent
through the interface.This counter
is the 64-bit edition of Out Octets.
The number of unicast packets
sent through the interface.
The number of multicast packets
sent through the interface.
The number of broadcast packets
sent through the interface.
Media counters for the comunica-
tions port.
Number of frames received that
were not octets in length.This
counter is the 64-bit edition of
Alignment Errors.
Number of frames received that
did not pass the FCS check.This
counter is the 64-bit edition of
FCS Errors.
The number of frames that failed
to be sent due to an internal MAC
sublayer transmission error.This
counter is the 64-bit edition of
MAC Transmit Errors.
The number of frames received
that exceeded the maximum
allowed frame size.This counter is
the 64-bit edition of Frame Too
Long.
The number of frames that could
not be received through the inter-
face due to an internal MAC sub-
layer reception error.This counter
is the 64-bit edition of MAC
Receive Errors.
The number of frames that could
not be received through the inter-
face due to an internal MAC sub-
layer symbol error.
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User's Manual (W563)
Read/write data
Attribute
Data
type
Read
Struct
---
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
Read
Struct
---
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
Value