F2: Analog Input Card Settings - YASKAWA A1000 HHP Programming Manual

High performance vector control drive
Table of Contents

Advertisement

1.6 F: Option Settings
Input pulse frequency from PG 60
r/min =
Pulses per Rev (F1-01/31)
No.
F1-12
F1-13
F1-33
F1-34
Note:
A gear ratio of 1 will be used if any of these parameters are set to 0.
n
F1-20, F1-36: PG Option Card Disconnect Detection
Sets whether the drive detects a PG hardware fault (PGoH).
No.
F1-20
PG Option Card Disconnection Detection 1
F1-36
PG Option Card Disconnection Detection 2
Setting 0: Disabled
Setting 1: Enabled
n
F1-21, F1-37: PG 1, PG 2 Signal Selection (V/f w/PG only)
Determines whether the signal to the PG option card is single-channel or two-channel.
No.
F1-21
F1-37
Setting 0: Single-channel (A channel only)
Setting 1: Two-channel (channels A and B)
n
F1-30: PG Option Card Port for Motor 2 Selection
Specifies the drive port for the PG option card used for motor 2. Set this parameter when switching between motor 1 and motor
2, where both motors supply a speed feedback signal to the drive. Set F1-30 to 0 when using the same PG card for feedback
signals from both motors. Set F1-30 to 1 when each motor has its own PG card connected to the drive.
Note:
The motor 2 selection function cannot be used with PM motors.
No.
F1-30
Setting 0: CN5-C
Setting 1: CN5-B
u

F2: Analog Input Card Settings

These parameters set the drive for operation with the analog input option card AI-A3. If no AI-A3 card is connected, drive
terminals A1 to A3 are enabled regardless of the F2-01 setting. This section describes parameters that govern operation with
an input option card. Refer to the option card instruction manual for specific details on installation, wiring, input signal level
selection, and parameter setup.
n
F2-01: Analog Input Option Card Operation Selection
Determines how the input terminals on the AI-A3 option card are used.
No.
F2-01
86
Load-side PG gear teeth (F1-12/33)
Motor-side PG gear teeth (F1-13/34)
Parameter Name
PG 1 Gear Teeth 1
PG 1 Gear Teeth 2
PG 2 Gear Teeth 1
PG 2 Gear Teeth 2
Parameter Name
Parameter Name
PG 1 Signal Selection
PG 2 Signal Selection
Parameter Name
PG Option Card Port for Motor 2 Selection
Parameter Name
Analog Input Option Card Operation Selection
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
Option Port
Setting Range
CN5-C
0 to 1000
CN5-C
0 to 1000
CN5-B
0 to 1000
CN5-B
0 to 1000
Option Port
Setting Range
CN5-C
CN5-B
Option Port
Setting Range
CN5-C
CN5-B
Setting Range
Setting Range
Default
0
0
0
0
Default
0, 1
1
0, 1
1
Default
0, 1
0
0, 1
0
Default
0, 1
1
Default
0, 1
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents