YASKAWA A1000 HHP Programming Manual page 182

High performance vector control drive
Table of Contents

Advertisement

2.3 Drive Alarms, Faults, and Errors
Digital Operator
Display
THo
Thermistor Disconnect
<2>
TrPC
IGBT Maintenance Time (90%)
UL3
Undertorque 1
UL4
Undertorque 2
<1> Output when H2-oo = 2F.
<2> Detected in models CIMR-Ao4A0930, 4A1200 and A1000 HHP.
<3> Terminals H1, H2, DM+, and DM- on 600 V class models are designed to the functionality, but are not certified to IEC/EN 61800-5-1, ISO/EN
13849 Cat. 3, IEC/EN 61508 SIL2, Insulation coordination: class 1.
n
Operation Errors
Digital Operator
Display
oPE01
Drive Unit Setting Error
oPE02
Parameter Setting Range Error
oPE03
Multi-Function Input Setting Error
oPE04
Terminal Board Mismatch Error
oPE05
Run Command Selection Error
oPE06
Control Method Selection Error
Multi-Function Analog Input Selection
oPE07
Error
n
Auto-Tuning Errors
Digital Operator
Display
End1
Excessive V/f Setting
Motor Iron Core Saturation Coefficient
End2
Error
End3
Rated Current Setting Alarm
Adjusted Slip Value Fell Below Lower
End4
Limit
End5
Resistance Between Lines Error
End6
Leakage Inductance Alarm
End7
No-Load Current Alarm
Er-01
Motor Data Error
Er-02
Alarm
Er-03
STOP Button Input
Er-04
Line-to-Line Resistance Error
Er-05
No-Load Current Error
n
Errors and Displays When Using the Copy Function
Digital Operator
Display
CoPy
Writing Parameter Settings (flashing)
CPEr
Control Mode Mismatch
CPyE
Error Writing Data
CSEr
Copy Unit Error
182
Minor Fault
Output
Name
(H2-oo =
10)
YES
YES
YES
YES
Table 2.7 Operation Error Displays
Name
Table 2.8 Auto-Tuning Error Displays
Name
Table 2.9 Copy Errors
Name
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
Digital Operator
Page
Display
Mechanical Weakening
UL5
211
Detection 2
Uv
Undervoltage
211
voF
Output Voltage Detection Fault
211
211
Digital Operator
Page
Display
213
oPE08
213
oPE09
213
oPE10
214
oPE13
214
oPE15
214
oPE16
oPE18
214
Digital Operator
Page
Display
217
Er-08
Er-09
217
Er-10
217
Er-11
217
Er-12
Er-13
217
Er-14
217
Er-15
218
Er-17
218
Er-18
218
Er-19
218
Er-20
218
Er-21
218
Digital Operator
Page
Display
222
dFPS
222
End
222
iFEr
222
Minor Fault
Output
Name
(H2-oo =
Name
Parameter Selection Error
PID Control Selection Error
V/f Data Setting Error
Pulse Train Monitor Selection Error
Torque Control Setting Error
Energy Saving Constants Error
Online Tuning Parameter Setting Error
Name
Rated Slip Error
Acceleration Error
Motor Direction Error
Motor Speed Error
Current Detection Error
Leakage Inductance Error
Motor Speed Error 2
Torque Saturation Error
Reverse Prohibited Error
Induction Voltage Error
PM Inductance Error
Stator Resistance Error
Z Pulse Correction Error
Name
Drive Model Mismatch
Task Complete
Communication Error
Page
10)
YES
200
YES
211
YES
212
Page
215
215
215
216
216
216
216
Page
219
219
219
219
219
220
220
220
220
220
220
220
221
Page
222
222
222

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents