YASKAWA A1000 HHP Programming Manual page 330

High performance vector control drive
Table of Contents

Advertisement

B.9 MEMOBUS/Modbus Data Table
Register No.
Data Link Status
bit 0
bit 1
bit 2
0022H
bit 3
bit 4
bit 5
bit 6 to bit F
0023H
U1-01 Frequency Reference
0024H
U1-02 Output Frequency
0025H
U1-06 Output Voltage Reference, 0.1 V units (units are determined by parameter H5-10)
0026H
U1-03Output Current, 0.1 A units
0027H
U1-08 Output Power
0028H
U1-09 Torque Reference
Fault Contents 2
bit 0
bit 1
bit 2
0029H
bit 3
bit 4
bit 5
bit 6
bit 7 to bit F
Alarm Contents 1
bit 0, 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
002AH
bit 8
bit 9
bit A
bit B
bit C
bit D
bit E
bit F
U1-10 Input Terminal Status
bit 0
bit 1
bit 2
bit 3
002BH
bit 4
bit 5
bit 6
bit 7
bit 8 to bit F
330
Writing data or switching motors
Reserved
Upper or lower limit error
Data conformity error
Writing to EEPROM
Reserved
<1>
<1>
IGBT Short Circuit (SC)
Ground Fault (GF)
Input Phase Loss (PF)
Output Phase Loss (LF)
Braking Resistor Overheat (rH)
Reserved
Motor Overheat 2 (PTC input) (oH4)
Reserved
Reserved
Run Command Input Error (EF)
Drive Baseblock (bb)
Overtorque Detection 1 (oL3)
Heatsink Overheat (oH)
Overvoltage (ov)
Undervoltage (Uv)
Cooling Fan Error (FAn)
MEMOBUS/Modbus Communication Error (CE)
Option Communication Error (bUS)
Undertorque Detection 1/2 (UL3/UL4)
Motor Overheat (oH3)
PID Feedback Loss (FbL, FbH)
Reserved
Serial Communication Transmission Error (CALL)
Terminal S1 Closed
Terminal S2 Closed
Terminal S3 Closed
Terminal S4 Closed
Terminal S5 Closed
Terminal S6 Closed
Terminal S7 Closed
Terminal S8 Closed
Reserved