A.15 U: Monitors
A.15 U: Monitors
Monitor parameters allow the user to view drive status, fault information, and other data concerning drive operation.
u

U1: Operation Status Monitors

No.
(Addr.
Name
Hex)
U1-01
Frequency Reference
(40)
U1-02
Output Frequency
(41)
U1-03
Output Current
(42)
U1-04
Control Method
(43)
U1-05
Motor Speed
(44)
U1-06
Output Voltage Reference
(45)
U1-07
DC Bus Voltage
(46)
U1-08
Output Power
(47)
U1-09
Torque Reference
(48)
U1-10
Input Terminal Status
(49)
298
Description
All Modes
Monitors the frequency reference. Display units are determined by o1-03.
All Modes
Displays the output frequency. Display units are determined by o1-03.
All Modes
Displays the output current.
Note:
This parameter is only available in models CIMR-
Ao4A0930, 4A1200, and A1000 HHP.
All Modes
0: V/f Control
1: V/f Control with PG
2: Open Loop Vector Control
3: Closed Loop Vector Control
V/f
V/f
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
Displays the motor speed feedback. Display units are determined by o1-03.
All Modes
Displays the output voltage.
All Modes
Displays the DC bus voltage.
All Modes
Displays the output power (this value is calculated internally).
V/f
V/f
V/f w PG
V/f w PG
OLV
OLV
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
Monitors the internal torque reference.
All Modes
Displays the input terminal status.
U1 - 10=
00000000
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
1
Digital input 1
(terminal S1 enabled)
1
Digital input 2
(terminal S2 enabled)
1
Digital input 3
(terminal S3 enabled)
1
Digital input 4
(terminal S4 enabled)
1
Digital input 5
(terminal S5 enabled)
1
Digital input 6
(terminal S6 enabled)
1
Digital input 7
(terminal S7 enabled)
1
Digital input 8
(terminal S8 enabled)
Analog Output
Unit
Level
10 V: Max frequency
0.01 Hz
10 V: Max frequency
0.01 Hz
10 V: Drive rated
<1> <2>
current
No signal output
available
10 V: Max frequency
0.01 Hz
<3>
0.1 Vac
10 V: 200 Vrms
<3>
1 Vdc
10 V: 400 V
10 V: Drive rated power
<4>
(kW)
10 V: Motor rated
0.1%
torque
No signal output
available