YASKAWA A1000 HHP Programming Manual page 223

High performance vector control drive
Table of Contents

Advertisement

Digital Operator Display
A non-compatible cable is being used to connect
the USB Copy Unit and the drive.
Digital Operator Display
Cause
The drive from which the parameters were copied
and the drive to which the parameters will be
written have different electrical specifications,
capacities, are set to different control modes, or are
different models.
The device being used to write the parameters is
blank and does not have any parameters saved on
it.
Digital Operator Display
Cause
Failed while attempting to read parameter settings
from the drive.
Digital Operator Display
Cause
Displayed while the parameter settings are being
read onto the USB Copy Unit.
Digital Operator Display
Cause
The drive from which the parameters were copied
and the drive on which the Verify mode is being
performed have different electrical specifications
or are a different capacity.
Digital Operator Display
Cause
Indicates that parameter settings that have been
Read and loaded onto the Copy Unit or Digital
Operator are different.
Digital Operator Display
Cause
The Verify mode has confirmed that parameters
settings on the drive and parameters read to the copy
device are identical.
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
Use the cable originally packaged with the USB Copy Unit.
ndAT
Model, Voltage Class, Capacity Mismatch
Make sure model numbers and specifications are the same for both drives.
Make sure all connections are correct, and copy the parameter settings onto the USB Copy Unit or
the operator.
rdEr
Error Reading Data
Press and hold the READ key on the USB Copy Unit for at least one second to have the unit read
parameters from the drive.
rEAd
Reading Parameter Settings (flashing)
This is not an error.
vAEr
Voltage Class, Capacity Mismatch
Make sure electrical specifications and capacities are the same for both drives.
vFyE
Parameter settings in the drive and those saved to the copy function are not the same
To synchronize parameters, either write the parameters saved on the USB Copy Unit or digital
operator onto the drive, or Read the parameter settings on the drive onto the USB Copy Unit.
vrFy
Comparing Parameter Settings (flashing)
This is not an error.
2.8 Copy Function Related Displays