YASKAWA A1000 HHP Programming Manual page 218

High performance vector control drive
Table of Contents

Advertisement

2.7 Auto-Tuning Fault Detection
Digital Operator Display
End7
Cause
The entered no-load current value was
outside the allowable range.
Auto-Tuning results were less than 5% of
the motor rated current.
Digital Operator Display
Er-01
Cause
Motor data or data entered during
Auto-Tuning was incorrect
.
Motor output power and motor-rated
current settings (T1-02 and T1-04) do not
match.
Motor rated current and detected no-load
current are inconsistent.
Base frequency and motor rated speed
(T1-05 and T1-07) do not match.
Digital Operator Display
Er-02
Cause
An alarm was triggered during Auto-
Tuning.
Digital Operator Display
Er-03
Cause
Auto-Tuning canceled by pressing STOP
button.
Digital Operator Display
Er-04
Cause
Motor data entered during Auto-Tuning
was incorrect.
Results from Auto-Tuning are outside the
parameter setting range or the tuning
process took too long.
Faulty motor cable or cable connection.
Digital Operator Display
Er-05
Cause
Motor data entered during Auto-Tuning
was incorrect.
Results from Auto-Tuning are outside the
parameter setting range or the tuning
process took too long.
The load was too high during Rotational
Auto-tuning.
218
No-Load Current Alarm
Check and correct faulty motor wiring.
Double-check the data entered for the Auto-Tuning process.
Motor Data Error
• Check that the motor data entered to T1 parameters matches motor nameplate input before Auto-Tuning.
• Restart Auto-Tuning and enter the correct information.
• Check the drive and motor capacities.
• Correct the settings of parameters T1-02 and T1-04.
• Check the motor rated current and no-load current.
• Correct the settings of parameters T1-04 and E2-03.
• Correct the settings of parameters T1-05 and T1-07.
• Check that the correct number of poles were entered to T1-06.
Minor Fault
Exit the Auto-Tuning menu, check the alarm code, remove the alarm cause, and repeat Auto-Tuning.
STOP Button Input
Auto-Tuning did not complete properly. Restart Auto-Tuning.
Line-to-Line Resistance Error
• Make sure the data entered to the T1 parameters match the information written on the motor nameplate.
• Restart Auto-Tuning and enter the correct information.
Check and correct faulty motor wiring.
No-Load Current Error
• Make sure the data entered to the T1 parameters match the information written on the motor nameplate.
• Restart Auto-Tuning and enter the correct information.
• Check and correct faulty motor wiring.
• Perform Rotational Auto-Tuning.
• Disconnect the motor from machine and restart Auto-Tuning. If motor and load cannot be uncoupled make
sure the load is lower than 30%.
• If a mechanical brake is installed, make sure it is fully lifted during tuning.
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions

Hide quick links:

Advertisement

Table of Contents
loading