Additional system components
7.4 Terminal Module TM31
7.4.7

Technical data

Table 7- 35
Technical data
Electronic power supply
Voltage
Current (without DRIVE-CLiQ or digital
outputs)
Power loss
PE/ground connection
Response time
Weight
192
Unit
V
DC
A
DC
W
On enclosure with M4/1.8 Nm screw
The response time for the digital inputs/outputs and the analog inputs/outputs
consists of the following elements:
Response time on the component itself (approx. 1/2 DRIVE-CLiQ cycle).
Transmission time via the DRIVE-CLiQ connection (approx. 1 DRIVE-CLiQ
cycle)
Evaluation on the Control Unit (see function diagram)
References: SINAMICS DCM List Manual, "Function diagrams" chapter
kg
Value
24 DC (20.4 – 28.8)
0.5
< 10
1
SINAMICS DCM Control Module