Encoder data - incremental encoder
Figure 8-24
Entering the encoder data
⇒ Enter the encoder type (usually HTL/TTL), the number of pulses per revolution, the level
and the zero mark configuration
CAUTION
Terminal X177.41 always delivers +15 V to supply the incremental encoder. That is
independent of the "voltage supply" setting selected in the box.
Note
The SMC30 supplies 5 V / 24 V encoder supply.
⇒ Click Continue >
Encoder data - Actual EMF value
⇒ Enter the tachometer voltage at maximum speed.
⇒ Click Continue >
SINAMICS DCM Control Module
Operating Instructions, 06.2010, C98130-A7067-A1-02-7619
8.4 Commissioning with the STARTER commissioning tool
Commissioning
227