Siemens SINAMICS DCM Operating Instructions Manual page 138

Control module for variable-speed dc drives
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Connecting
6.16 Connector assignment (terminals, Faston mounting tabs, ribbon cables)
Firing pulse cable, torque direction 2, connectors X22A/X22PAR
Ribbon cable, 26-pin
Table 6- 25
Assignment X22A, X22PAR
Function
Free
Free
Free
Electronic ground
Thyristor firing pulse, armature 2
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 6
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 4
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 5
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 3
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 1
24 V supply, firing
Electronic ground
Free
Free
Electronic ground
Free
Power interface C98043-A7109/Firing pulse module C98043-A7043
Connectors X22A and X22PAR are connected in parallel on module C98043-A7043.
138
Pin
Signal name
1
2
3
4
M
5
IMP_22
6
P24_Z
7
M
8
IMP_26
9
P24_Z
10
M
11
IMP_24
12
P24_Z
13
M
14
IMP_25
15
P24_Z
16
M
17
IMP_23
18
P24_Z
19
M
20
IMP_21
21
P24_Z
22
M
23
24
25
M
26
Operating Instructions, 06.2010, C98130-A7067-A1-02-7619
Connection
values/Comments
24 V/2 A pulse
24 VDC/2 A
24 V/2 A pulse
24 VDC/2 A
24 V/2 A pulse
24 VDC/2 A
4 V/2 A pulse
24 VDC/2 A
24 V/2 A pulse
24 VDC/2 A
24 V/2 A pulse
24 VDC/2 A
SINAMICS DCM Control Module

Advertisement

Table of Contents
loading

Table of Contents