Voltage Measurement Equipment - Siemens SINAMICS DCM Operating Instructions Manual

Control module for variable-speed dc drives
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

6.16.5

Voltage measurement equipment

Connection type: Faston mounting tabs, 4.8 mm
Table 6- 20
Voltage measurement connections
Connection
Function
XU1
Measurement of line voltage
XV1
Phases U-V-W
XW1
(1,000 V)
XC1
Measurement of armature
XD1
voltage
(1,000 V)
XU2
Measurement of line voltage
XV2
Phases U-V-W
XW2
(575 V)
XC2
Measurement of armature
XD2
voltage
(575 V)
XU3
Measurement of line voltage
XV3
Phases U-V-W
XW3
(250 V)
XC3
Measurement of armature
XD3
voltage
(250 V)
XU4
Measurement of line voltage
XV4
Phases U-V-W
XW4
(125 V)
XC4
Measurement of armature
XD4
voltage
(125 V)
XU5
Measurement of line voltage
XV5
Phases U-V-W
XW5
(50 V)
XC5
Measurement of armature
XD5
voltage
(50 V)
XU6
Measurement of line voltage
XV6
Phases U-V-W
XW6
(5.6 V)
XC6
Measurement of armature
XD6
voltage
(5.6 V)
Module C98043-A7117, voltage measurement equipment
SINAMICS DCM Control Module
Operating Instructions, 06.2010, C98130-A7067-A1-02-7619
6.16 Connector assignment (terminals, Faston mounting tabs, ribbon cables)
Technical data, comments
Rated line voltage (armature) >575 V to 1,000 V
(p51821 = 1,000)
Rated line voltage (armature) >575 V to 1,000 V
(p51821 = 1,000)
Rated line voltage (armature) >250 V to 575 V
(p51821 = 575)
Rated line voltage (armature) >250 V to 575 V
(p51821 = 575)
Rated line voltage (armature) >125 V to 250 V
(p51821 = 250)
Rated line voltage (armature) >125 V to 250 V
(p51821 = 250)
Rated line voltage (armature) >50 V to 125 V
(p51821 = 125)
Rated line voltage (armature) >50 V to 125 V
(p51821 = 125)
Rated line voltage (armature) >5.6 V to 50 V
(p51821 = 50)
Rated line voltage (armature) >5.6 V to 50 V
(p51821 = 50)
Rated line voltage (armature) ≤5.6 V
(p51821 = 6)
Rated line voltage (armature) ≤5.6 V
(p51821 = 6)
Connecting
129