Commissioning
8.4 Commissioning with the STARTER commissioning tool
Encoder data - Freely wired actual value
⇒ Enter the source with the actual value for the closed-loop controller via the BICO
interconnection.
⇒ Click Continue >
Encoder data – Encoder on the SMC30 evaluation module
Figure 8-25
Entering the encoder data (DRIVE-CLiQ)
⇒ Enter the encoder type (usually HTL/TTL), the number of pulses per revolution, the level
and the zero mark configuration
⇒ Click Continue >
228
SINAMICS DCM Control Module
Operating Instructions, 06.2010, C98130-A7067-A1-02-7619