External mounting of module parts
The parts required are not included in the scope of delivery, but are available as a "set of
loose parts" under order no. 6RY1807-0CM00.
The 3 snap-on parts
for the DIN rail, which satisfies DIN EN 50022-35x7.5, are mounted on the terminal strip with
spacer rollers
and M3x16 screws
Figure 5-9
External mounting of the terminal strip
The 2 snap-on parts
for the DIN rail, which satisfies DIN EN 50022-35x7.5, are mounted on the small control boards
with M3x8 screws
.
Figure 5-10
External mounting of the small firing pulse transformer boards