Descriptions of functions
10.28 Diagnostics
BI: p2106
BI: p2107
BI: p2108
BI: p2112
BI: p2116
BI: p2117
Note
An external fault or alarm is triggered by a 1/0 signal.
An external fault and alarm do not usually mean that an internal drive message has been
generated. The cause of an external fault and warning should, therefore, be remedied
outside the drive unit.
10.28.5.4

Parameters and function diagrams for faults and alarms

Function diagrams (see the SINAMICS DCM List Manual)
● 1710 Overview diagram – monitoring functions, faults, alarms
● 8060 Faults and alarms – fault buffer
● 8065 Faults and alarms – alarm buffer
● 8070 Faults and alarms – fault/alarm trigger word r2129
● 8075 Faults and alarms – fault/alarm configuration
Overview of important parameters (refer to the SINAMICS DCM List Manual)
● r0944 Counter for fault buffer changes
● p0952 Fault incident counter
● p2100[0...19] Fault code for fault reaction selection
● r2139 Status word for faults
458
→ External fault 1
→ External fault 2
→ External fault 3
→ External alarm 1
→ External alarm 2
→ External alarm 3
...
...
→ F07860(A)
→ F07861(A)
→ F07862(A)
→ A07850(F)
→ A07851(F)
→ A07852(F)
SINAMICS DCM Control Module
Operating Instructions, 06.2010, C98130-A7067-A1-02-7619