50
Merlin PLUS User Manual v2.0
5. Select Disable when connecting to Tieline codecs using session data, or select Enable if
connecting to non-Tieline codecs only, then press the
Important Note: Select Disable if the codec is expected to receive POTS calls from
Tieline codecs, or both Tieline and non-Tieline codecs (i.e. you are not sure which type of
codec may call). In this mode, once the codec answers a call, it expects to receive
Tieline session data from the caller and configure its own algorithm settings according to
that. If it fails to receive Tieline session data within 5 seconds (e.g. a Comrex POTS
codec is calling), it will use the settings in the POTS Answering Config instead.
Enable Sessionless Only when answering POTS calls from non-Tieline codecs only.
When Sessionless is configured, the codec will not wait for the session data. This
reduces the time taken to answer an inbound sessionless call.
6. Select Other when connecting to Comrex® Vector, Matrix® and BlueBox® codecs, then press
the
button.
Important Note: On the Comrex codec select its "Music" algorithm. Please note that
9.6kbps connections are not supported by the Comrex codecs.
7. If required you can specify the audio stream Route when answering a call from a non-Tieline
codec, then press the
8. Select Yes and press the
9. The new Config will be displayed showing the updated settings.
button.
button to confirm the new Config settings.
button.
© Tieline Pty. Ltd. 2017
Need help?
Do you have a question about the Merlin PLUS and is the answer not in the manual?