Answer Routes for Non-Tieline POTS Codecs
In some situations you may receive a call from a non-Tieline POTS codec which doesn't support
Dial Route tags. In this situation you can still specify the audio stream Route on the answering
codec using Config 1 or 2 in POTS Answer. You can also select the default algorithm.
For example, if a call from a non-Tieline codec is received via POTS Module 1 (i.e. no Dial Route
has been specified in the dialing codec):
1. Click the Edit button to configure settings.
2. Select an answering Route for this POTS module in one of the two Configs available in the
POTS Answer panel, e.g. Route1, then select the default Encoding algorithm Other
(Note: Other is used for connecting to Comrex POTS codecs).
3. Click Save to store the new Config settings.
4. This will associate the incoming call with a corresponding Answer Route configured in the
codec answering program, e.g. Answer Route 1 as displayed in the following example.
23.7
Configuring Input/Output Settings
Open the HTML5 Toolbox Web-GUI and click
display the
© Tieline Pty. Ltd. 2017
panel.
Inputs
Merlin PLUS User Manual v2.0
Audio in the Menu Bar, then click
139