Tieline Merlin PLUS User Manual page 237

Ip / isdn / pots codec for 6 simultaneous remotes -
Hide thumbs Also See for Merlin PLUS:
Table of Contents

Advertisement

5. Click Save to store the new settings.
Note: The following System and Audio alarms are available:
Alarm
PSU Failure
Input Silence
Connection Lost
Temperature
AES Reference Lost
AES Input Lost
Program Failure
Scheduled Event Failed
Edit an Alarm's Severity Level
Codec alarms can be configured for three different severity levels:
1. Click to select an alarm from those displayed in the Configure alarms panel.
2. Click Edit to configure alarm settings.
3. Click the Alarm Severity drop-down menu and select the preferred severity level.
© Tieline Pty. Ltd. 2017
Alarm
Explanation
Type
System
Raises an alarm if one or both PSUs fail
Audio
Raises an alarm if input audio is lost (according to
preconfigured silence detection threshold parameters)
Audio
Triggers and alarm whenever a streaming connection is
lost
System
Raises an alarm if the temperature is too low or too high
Audio
Raises an alarm if the AES reference clock signal is lost
(not available in WheatNet-IP capable codecs)
Audio
Raises an alarm if the AES input signal is lost (not
available in WheatNet-IP capable codecs)
Audio
An element within a configured program has failed and
has not been terminated manually. Note: the alarm is
cleared if the program is unloaded.
Audio
A scheduled event could not be started or stopped at the
specified time. Note: the alarm is only present for the
duration of the event.