Networking Configuration Examples; One Voip Interface For All Applications; Voip Interface Per Application Type - AudioCodes Mediant 600 User Manual

Voip media gateways analog & digital lines
Hide thumbs Also See for Mediant 600:
Table of Contents

Advertisement

User's Manual

11.3.4 Networking Configuration Examples

This section provides configuration examples of networking interfaces.

11.3.4.1 One VoIP Interface for All Applications

This example describes the configuration of a single VoIP interface for all applications:
1.
Multiple Interface table: Configured with a single interface for OAMP, Media and
Control:
Example of Single VoIP Interface in Multiple Interface Table
Application
Index
Type
0
OAMP, Media
& Control
2.
VLANS are not required and the Native VLAN ID is irrelevant. Class of Service
parameters may have default values.
3.
IP Routing table: Two routes are configured for directing traffic for subnet
201.201.0.0/16 to 192.168.0.2, and all traffic for subnet 202.202.0.0/16 to 192.168.0.3:
Destination IP
Address
201.201.0.0
202.202.0.0
4.
The NTP applications remain with their default application types.

11.3.4.2 VoIP Interface per Application Type

This example describes the configuration of three VoIP interfaces; one for each application
type:
1.
Multiple Interface table: Configured with three interfaces, each for a different
application type, i.e., one for OAMP, one for Call Control, and one for RTP Media, and
each with a different VLAN ID and default gateway:
Example of VoIP Interfaces per Application Type in Multiple Interface Table
Application
Index
Type
0
OAMP
1
Control
2
Media
Version 6.6
Prefix
IP Address
Length
192.168.85.14
16
Example of IP Routing Table
Prefix Length
16
16
Prefix
IP Address
Length
192.168.85.14
16
200.200.85.14
24
211.211.85.14
24
117
Default
VLAN ID
192.168.0.1
1
Gateway IP Address
192.168.0.2
192.168.0.3
Gateway
VLAN ID Interface Name
0.0.0.0
1
200.200.85.1
200
211.211.85.1
211
Mediant 600 & Mediant 1000
11. Network
Interface Name
myInterface
Metric
1
1
ManagementIF
myControlIF
myMediaIF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mediant 1000

Table of Contents