AudioCodes Mediant 600 User Manual page 505

Voip media gateways analog & digital lines
Hide thumbs Also See for Mediant 600:
Table of Contents

Advertisement

User's Manual
This cadence rings once during the ringing pattern. Otherwise, the cadence is
interpreted as cyclic: it repeats for every ringing cycle.
Ring On Time: Specifies the duration of the ringing signal.
Ring Off Time: Specifies the silence period of the cadence.
The Distinctive Ringing section of the ini file format contains the following strings:
[NUMBER OF DISTINCTIVE RINGING PATTERNS]: Contains the following key:
'Number of Distinctive Ringing Patterns' defining the number of Distinctive
Ringing signals that are defined in the file.
[Ringing Pattern #X]: Contains the Xth ringing pattern definition (starting from 0 and
not exceeding the number of Distinctive Ringing patterns defined in the first section
minus 1) using the following keys:
Ring Type: Must be equal to the Ringing Pattern number.
Freq [Hz]: Frequency in hertz of the ringing tone.
First (Burst) Ring On Time [10 msec]: 'Ring On' period (in 10 msec units) for
the first cadence on-off cycle.
First (Burst) Ring Off Time [10 msec]: 'Ring Off' period (in 10 msec units) for
the first cadence on-off cycle.
Second (Burst) Ring On Time [10 msec]: 'Ring On' period (in 10 msec units)
for the second cadence on-off cycle.
Second (Burst) Ring Off Time [10 msec]: 'Ring Off' period (in 10 msec units)
for the second cadence on-off cycle.
Third (Burst) Ring On Time [10 msec]: 'Ring On' period (in 10 msec units) for
the third cadence on-off cycle.
Third (Burst) Ring Off Time [10 msec]: 'Ring Off' period (in 10 msec units) for
the third cadence on-off cycle.
Fourth (Burst) Ring On Time [10 msec]: 'Ring Off' period (in 10 msec units) for
the fourth cadence on-off cycle.
Fourth (Burst) Ring Off Time [10 msec]: 'Ring Off' period (in 10 msec units) for
the fourth cadence on-off cycle.
Note:
An example of a ringing burst definition is shown below:
#Three ringing bursts followed by repeated ringing of 1 sec on and
3 sec off.
[NUMBER OF DISTINCTIVE RINGING PATTERNS]
Number of Ringing Patterns=1
[Ringing Pattern #0]
Ring Type=0
Freq [Hz]=25
First Burst Ring On Time [10msec]=30
First Burst Ring Off Time [10msec]=30
Second Burst Ring On Time [10msec]=30
Second Burst Ring Off Time [10msec]=30
Third Burst Ring On Time [10msec]=30
Third Burst Ring Off Time [10msec]=30
Version 6.6
In SIP, the Distinctive Ringing pattern is selected according to the Alert-Info
header in the INVITE message. For example:
Alert-Info:<Bellcore-dr2>, or Alert-Info:<http://.../Bellcore-dr2>
'dr2' defines ringing pattern #2. If the Alert-Info header is missing, the default
ringing tone (0) is played.