Gateway Operational State:
"LOCKED": device is locked (i.e. no new calls are accepted)
"UNLOCKED": device is not locked
"SHUTTING DOWN": device is currently shutting down
To perform these operations, see 'Basic Maintenance' on page 491.
The table below describes the areas of the Home page.
Item #
1
Displays the highest severity of an active alarm raised (if any) by the device:
Green: No alarms
Red: Critical alarm
Orange: Major alarm
Yellow: Minor alarm
To view active alarms, click the Alarms area to open the Active Alarms page (see
Viewing Active Alarms on page 543).
2
Module slot number.
3
Module type (e.g., FXS, FXO, and DIGITAL)
4
Module status icon:
(green): Module has been inserted or is correctly configured
(gray): Module was removed and "Reserved" is displayed
(red): Module failure and "Failure" is displayed
5
Port (trunk or channel) status icon.
Icon
(grey)
(green)
(yellow)
(red)
(blue)
(light orange)
User's Manual
Home Page Description
Description
Trunk Description
(Digital Module)
Disable: Trunk not configured (not
in use)
Active - OK: Trunk synchronized
RAI Alarm: Remote Alarm
Indication (RAI), also known as the
Yellow Alarm
LOS / LOF Alarm: Loss due to LOS
(Loss of Signal) or LOF (Loss of
Frame)
AIS Alarm: Alarm Indication Signal
(AIS), also known as the Blue
Alarm
D-Channel Alarm: D-channel alarm
62
Mediant 600 & Mediant 1000
Channel Description
(Analog Module)
Idle: Channel is currently on-
hook
Call Connected: Active RTP
stream
-
Not Connected: No analog
line is connected to this port
or port out of service due to
Serial Peripheral Interface
(SPI) failure (applicable only
to FXO interfaces)
Handset Offhook: Channel is
off-hook, but there is no
active RTP session
-
Document #: LTRT-83313