Notes:
Parameter
Filter Type
CLI: filter-type
[LoggingFilters_Ty
pe]
Value
CLI: value
[LoggingFilters_Val
ue]
Syslog
[LoggingFilters_Sy
slog]
User's Manual
To configure the Syslog debug level, use the 'Debug Level' parameter
(see 'Configuring Syslog' on page 583).
The Logging Filters table can also be configured using the table ini file
parameter, LoggingFilters.
Logging Filters Table Parameters Description
Defines the filter criteria.
[1] Any (default)
[2] Trunk ID = Filters according to a specified Trunk ID (applicable only
to the Gateway application).
[3] Trunk Group ID = Filters according to a specified Trunk Group ID
(Applicable only to the Gateway/IP-to-IP application).
[4] Trunk & B-channel = Filters according to a specified Trunk and B-
channel (applicable only to the Gateway/IP-to-IP application).
[5] FXS or FXO = Filters according to a specified FXS or FXO port.
[6] Tel-to-IP = Filters according to a specified Tel-to-IP routing rule listed
in the Outbound IP Routing table (applicable only to the Gateway/IP-to-
IP application).
[7] IP-to-Tel = Filters according to a specified IP-to-Tel routing rule listed
in the Inbound IP Routing table (applicable only to the Gateway/IP-to-IP
application).
[8] IP Group = Filters according to a specified IP Group ID listed in the IP
Group table.
[9] SRD = Filters according to a specified SRD ID listed in the SRD
table.
[12] User = Filters according to a specified user defined by username or
user@host.
[13] IP Trace = Filters according to a specified IP network trace
wireshark-like expression. For a detailed description on configuring IP
traces, see 'Filtering IP Network Traces' on page 587.
Defines the value of the selected filtering type in the 'Filter Type' parameter.
The value can be the following:
A single value
A range, using a hyphen "-" between the two values, e.g., "1-3"
Multiple, non-contiguous values, using commas "," between each value,
e.g., "1,3,9"
Trunks and FXO/FXS pertaining to a module, using the syntax module
number/port or port, for example:
"1/2", means module 1, port 2
"1/[2-4]", means module 1, ports 2 through 4
Any to indicate all
For IP trace expressions, see e 'Filtering IP Network Traces' on page
587
Enables Syslog messages for the defined logging filter:
[0] Disable (default)
[1] Enable
Description