Parameter
Web/EMS: Enable Caller
ID
[EnableCallerID]
Web: Caller ID Type
EMS: Caller id Types
[CallerIDType]
User's Manual
CallerDisplayInfo_IsCidRestricted, CallerDisplayInfo_Module,
CallerDisplayInfo_Port;
[\CallerDisplayInfo]
Where,
Module = Module number, where 1 denotes the module in Slot 1.
Port = Port number, where 1 denotes Port 1 of a module.
For example:
CallerDisplayInfo 0 = Susan C.,0,1,1;
Caller ID for Port 1 of Module 1)
CallerDisplayInfo 1 = Mark M.,0,1,2;
for Port 2 of Module 1)
Notes:
The indexing of this table ini file parameter starts at 0.
For a detailed description of this table, see Configuring Caller
Display Information on page 396.
Enables Caller ID.
[0] Disable (default)
[1] Enable
If the Caller ID service is enabled, then for FXS interfaces, calling
number and Display text (from IP) are sent to the device's port.
For FXO interfaces, the Caller ID signal is detected and sent to IP in
the SIP INVITE message (as 'Display' element).
For information on the Caller ID table, see Configuring Caller Display
Information on page 396.
To disable/enable caller ID generation per port, see Configuring Call
Forward on page 397.
Determines the standard used for detection (FXO) and generation
(FXS) of Caller ID, and detection (FXO) / generation (FXS) of MWI
(when specified) signals:
[0] Standard Bellcore = (Default) Caller ID and MWI
[1] Standard ETSI = Caller ID and MWI
[2] Standard NTT
[4] Standard BT = Britain
[16] Standard DTMF Based ETSI
[17] Standard Denmark = Caller ID and MWI
[18] Standard India
[19] Standard Brazil
Notes:
Typically, the Caller ID signals are generated / detected between
the first and second rings. However, sometimes the Caller ID is
detected before the first ring signal. In such a scenario, set the
RingsBeforeCallerID parameter to 0.
Caller ID detection for Britain [4] is not supported on the device's
FXO ports. Only FXS ports can generate the Britain [4] Caller ID.
To select the Bellcore Caller ID sub standard, use the
BellcoreCallerIDTypeOneSubStandard parameter. To select the
ETSI Caller ID substandard, use the
ETSICallerIDTypeOneSubStandard parameter.
To select the Bellcore MWI sub standard, use the
BellcoreVMWITypeOneStandard parameter. To select the ETSI
MWI sub standard, use the ETSIVMWITypeOneStandard
722