Trunk Groups And Routing Parameters - AudioCodes Mediant 600 User Manual

Voip media gateways analog & digital lines
Hide thumbs Also See for Mediant 600:
Table of Contents

Advertisement

User's Manual
Parameter
Web: Rings before Detecting Caller
ID
EMS: Rings Before Caller ID
[RingsBeforeCallerID]
Web/EMS: Guard Time Between
Calls
[GuardTimeBetweenCalls]
Web: FXO Double Answer
[EnableFXODoubleAnswer]
52.11.12

Trunk Groups and Routing Parameters

The routing parameters are described in the table below.
Parameter
Trunk Group Table
Web: Trunk Group Table
EMS: SIP Endpoints >
Phones
[TrunkGroup]
Version 6.6
seconds on and four seconds off, the timeout value should
be configured to five seconds (i.e., greater than the off
time, e.g., four).
Determines the number of rings before the device starts
detecting Caller ID.
[0] 0 = Before first ring.
[1] 1 = (Default) After first ring.
[2] 2 = After second ring.
Defines the time interval (in seconds) after a call has ended
and a new call can be accepted for IP-to-Tel (FXO) calls.
The valid range is 0 to 10. The default is 1.
Note: Occasionally, after a call ends and on-hook is applied,
a delay is required before placing a new call (and performing
off-hook). This is necessary to prevent incorrect hook-flash
detection or other glare phenomena.
Enables the FXO Double Answer feature, which rejects
(disconnects) incoming Tel (FXO)-to-IP collect calls and
signals (informs) this call denial to the PSTN.
[0] Disable (default)
[1] Enable
Note: This feature can also be configured in a Tel Profile.
Routing Parameters
This table parameter configures and activates the device's
endpoints/Trunk channels. This is done by defining telephone
numbers and assigning them to Trunk Groups. The format of this
parameter is shown below:
[TrunkGroup]
FORMAT TrunkGroup_Index = TrunkGroup_TrunkGroupNum,
TrunkGroup_FirstTrunkId, TrunkGroup_FirstBChannel,
TrunkGroup_LastBChannel, TrunkGroup_FirstPhoneNumber,
TrunkGroup_ProfileId, TrunkGroup_LastTrunkId,
TrunkGroup_Module;
[\TrunkGroup]
For example:
The configuration below assigns Trunk 1 (channels 1 to 30) of
Module 1 to Trunk Group ID 2:
TrunkGroup 0 = 2, 0, 1, 30, 50000, 0, 0, 1;
The configuration below assigns BRI channels 1 through 4 of Module
2 to Trunk Group ID 2 with phone numbers 208 to 211:
799