User Access
Level
Master
Security
Administrator
Administrator
Monitor
No Access
* The numeric representation of the access level is used only to define accounts in a RADIUS
server (the access level ranges from 1 to 255).
By default, the device is pre-configured with the following two Web user accounts:
User Access Level
Security Administrator
Monitor
After you log in to the Web interface, the username is displayed on the toolbar.
If the Web session is idle (i.e., no actions are performed) for more than five minutes, the
Web session expires and you are once again requested to login with your username and
password. Users can be banned for a period of time upon a user-defined number of
unsuccessful login attempts. Login information (such as how many login attempts were
made and the last successful login time) can be presented to the user.
To prevent user access after a specific number of failed logins:
1.
From the 'Deny Access On Fail Count' drop-down list, select the number of failed
logins after which the user is prevented access to the device for a user-defined time
(see next step).
2.
In the 'Deny Authentication Timer' field, enter the interval (in seconds) that the user
needs to wait before a new login attempt from the same IP address can be done after
reaching the number of failed login attempts (defined in the previous step).
Version 6.6
Access Levels of Web User Accounts
Numeric
Representation*
Read / write privileges for all pages. Can create all user
types, including additional Master users and Security
220
Administrators. It can delete all users except the last
Security Administrator.
Read / write privileges for all pages. It can create all user
types and is the only one that can create the first Master
200
user.
Note: There must be at least one Security Administrator.
Read / write privileges for all pages except security-
100
related pages, which are read-only.
No access to security-related and file-loading pages;
50
read-only access to other pages.
No access to any page.
Note: This access level is not applicable when using
0
advanced Web user account configuration in the Web
Users table.
Pre-configured Web User Accounts
Username
(Case-Sensitive)
Privileges
Admin
User
65
4. Web-Based Management
Password
(Case-Sensitive)
Admin
User
Mediant 600 & Mediant 1000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mediant 1000

Table of Contents