Removing The Battery Holder, Serveraid Li-Ion Battery, And Charge Circuit From A 3U Chassis - IBM System x iDataPlex dx360 M2 Problem Determination And Service Manual

Hide thumbs Also See for System x iDataPlex dx360 M2:
Table of Contents

Advertisement

Installing the mini-SAS RAID controller
To install the mini-SAS RAID controller, complete the following steps.
1. Touch the static-protective package that contains the mini-SAS RAID controller
2. Align the mini-SAS RAID controller with the mini-PCI connector on the system
3. Press the mini-SAS RAID controller downward until the release clips click into
4. If you disconnected a cable when you removed the mini-SAS RAID controller,
5. Install the enclosure, if you removed one (see "Installing an expansion
6. Install the system-board tray in the chassis (see "Installing the system-board
Removing the battery holder, ServeRAID Li-Ion battery, and charge
circuit from a 3U chassis
To remove the battery holder, ServeRAID Li-Ion battery, and charge circuit from a
3U chassis, complete the following steps.
156
System x iDataPlex dx360 M2: Problem Determination and Service Guide
to any unpainted metal surface on the outside of the system-board tray; then,
remove the adapter from the package.
board; then, press the adapter into the connector.
place and the plastic standoffs are seated in the system board.
reconnect the cable.
enclosure on a system-board tray" on page 132); otherwise, install the
system-board tray cover (see "Installing the system-board tray cover" on page
125).
tray in a 2U chassis" on page 127 or "Installing the system-board tray in a 3U
chassis" on page 129).
Note: To complete the installation of the mini-SAS RAID controller, see the
documentation that comes with the controller for device-driver and
configuration information.

Advertisement

Table of Contents
loading

Table of Contents