Table 2. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing," on page 109 to determine which components are customer replaceable units (CRU) and
which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
201-901-xxx
Memory
66
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Test
State
Description
Memory Test
Failed
Test failure:
single-bit error,
failing DIMM z.
Action
1. Turn off the system and disconnect it from the
power source.
2. Reseat DIMM z.
3. Reconnect the system to power and turn on the
system.
4. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
5. Make sure that the server firmware is at the
latest level. The installed firmware level is
shown in the diagnostic event log in the
Firmware/VPD section for this component. For
more information, see "Firmware updates" on
page 213.
6. Run the test again.
7. Replace the failing DIMMs.
8. Re-enable all memory in the Setup utility (see
"Using the Setup utility" on page 214).
9. Run the test again.
10. Replace the failing DIMM.
11. If the failure remains, go to the IBM Web site
for more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.