IBM System x iDataPlex dx360 M2 Problem Determination And Service Manual page 118

Hide thumbs Also See for System x iDataPlex dx360 M2:
Table of Contents

Advertisement

Table 3. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing," on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Message
SSL data in the IMM
configuration data is invalid.
Clearing configuration data
region and disabling
SSL+H25.
The Chassis Event Log
(CEL) on system %1 cleared
by user %2. (%1 =
CIM_ComputerSystem.
ElementName;
%2 = user ID)
The Chassis Event Log
(CEL) on system %1 is
100% full. (%1 =
CIM_ComputerSystem.
ElementName)
The Chassis Event Log
(CEL) on system %1 is 75%
full. (%1 =
CIM_ComputerSystem.
ElementName)
The Drive n Status has been
disabled due to a detected
fault.
(n = hard disk drive number)
The Drive n Status has
been removed from unit
Drive 0 Status.
(n = hard disk drive number)
102
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Severity
Description
Error
There is a problem with the
certificate that has been imported
into the IMM. The imported
certificate must contain a public key
that corresponds to the key pair
that was previously generated
through the Generate a New Key
and Certificate Signing Request
link.
Info
A user has cleared the IMM event
log.
Info
The IMM event log is full. When the
log is full, older log entries are
replaced by newer ones.
Info
The IMM event log is 75% full.
When the log is full, older log
entries are replaced by newer ones.
Error
A drive has been disabled because
of a fault.
Error
A drive has been removed.
Action
1. Make sure that the certificate
that you are importing is
correct.
2. Try to import the certificate
again.
No action; information only.
To avoid losing older log entries,
save the log as a text file and clear
the log.
To avoid losing older log entries,
save the log as a text file and clear
the log.
1. Run the hard disk drive
diagnostic test on drive n.
2. Reseat the following
components:
a. Hard disk drive
b. Cable from the system
board to the backplane
3. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. Hard disk drive
b. Cable from the system
board to the backplane
c. Hard disk drive backplane
(n = hard disk drive number)
Reseat hard disk drive n.
(n = hard disk drive number).

Advertisement