Table 3. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing," on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Message
Please ensure that the IMM
is flashed with the correct
firmware. The IMM is unable
to match its firmware to the
server.
Redundancy Bckup Mem
Status has been reduced.
Remote access attempt
failed. Invalid userid or
password received. Userid is
'%1' from TELNET client at
IP address %2.
(%1 = user ID;
%2 = IP address,
xxx.xxx.xxx.xxx)
Remote access attempt
failed. Invalid userid or
password received. Userid is
'%1' from WEB browser at IP
address %2.
(%1 = user ID;
%2 = IP address,
xxx.xxx.xxx.xxx)
Remote Login Successful.
Login ID: %1 from %2 at IP
address %3. (%1 = user ID;
%2 =
ValueMap(CIM_Protocol
Endpoint.ProtocolIFType;
%3 = IP address,
xxx.xxx.xxx.xxx)
Running the backup IMM
main application.
Severity
Description
Error
The server does not support the
installed IMM firmware version.
Error
Redundancy has been lost and is
insufficient to continue operation.
Error
A user has attempted to log in from
a Telnet session by using an invalid
login ID or password.
Error
A user has attempted to log in from
a Web browser by using an invalid
login ID or password.
Info
A user has successfully logged in to
the IMM.
Error
The IMM has resorted to running
the backup main application.
Action
Update the IMM firmware to a
version that the server supports.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
1. Check the system-event log for
DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2. Re-enable mirroring in the
Setup utility.
1. Make sure that the correct login
ID and password are being
used.
2. Have the system administrator
reset the login ID or password.
1. Make sure that the correct login
ID and password are being
used.
2. Have the system administrator
reset the login ID or password.
No action; information only.
Update the IMM firmware.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
Chapter 3. Diagnostics
99

Advertisement

Table of Contents
loading

Table of Contents