2. Align the ServeRAID Li-Ion battery and charge circuit and press together until
the tab snaps in place. Connect the cable from the ServeRAID Li-Ion battery to
the charge circuit.
3. Align the standoffs on the charge circuit with the tray and press together until
the tabs snap in place to secure the assembly.
4. Connect the battery cable to the ServeRAID Li-Ion battery and charge circuit
assembly.
5. Align the assembly in the battery holder and slide the assembly into the battery
holder until the tray retention tab snaps in place.
6. Feed the battery cable through the hard disk drive bay and slide the battery
holder into the bay until the retention tab secures the battery holder.
7. Install the hard disk drive bay filler panel.
Chapter 5. Removing and replacing server components
159